Brief Instroduction
The reaction kettle temperature control effect is to determine the product quality, production efficiency. Under normal circumstances the application of temperature control use different temperature heat transfer oil directly into the reactor jacket, in order to adjust the temperature transfer to the reactor, this often makes the reactor jacket fluid quite chaotic, kettle Temperature is difficult to achieve the expected results. In response to reslove this problem, we design a reactor oil circulating heater, the principle is to use the heat transfer oil through the pump, the heat through heat exchanger into the reactor, when it need to cool down, start the cooling system, at same time the heater stops working. Just to reach the temperature inside the reactor at the setting time, then it continue to keep the temperature, so only the usage of heat conducting oil heater can make the kettle temperature faster and more accurately to reach the best temperature.
Reactor temperature control machine, reactor heating oil circulation heating equipment selection parameters:
1, the size of the reactor;
2, the weight of reactor;
3, the reactor jacket or coil volume;
4, the reactor of the material parameters: density, specific heat, viscosity and so on
5, the reactor material required to achieve the temperature, and heating to the temperature of the time requirements;
6, reactor jacket is how much the import and export;
7, the need for refrigeration or explosion-proof;
8, whether the reactor can provide the drawings;
Model |
Unit |
HLET-10 |
HLET-20 |
HLET-30 |
HLET-40 |
HLET-50 |
HLET-75 |
HLET-100 |
HLET-150 |
Temp Range |
℃ |
Normal temperature-300℃ |
|||||||
Temp.Control Accuracy |
PID±1℃ |
||||||||
Power Supply |
AC3∮380V 50HZ3P+E(5M) |
||||||||
Heat Transfer Medium |
Qil |
||||||||
Cooling Method |
Indirect Cooling |
||||||||
Expansion Tank Capacity |
L |
24 |
24 |
28 |
55 |
55 |
(100) |
(150) |
(250) |
Heating Capacity |
KW |
18 |
18/24 |
24/36 |
36/50 |
40/60 |
50/75 |
80/100 |
100/150 |
Pump Power |
KW |
0.75 |
1.5 |
2.2 |
3.0 |
4.0 |
5.5 |
7.5 |
11.0 |
Pump Folw |
L/MIN |
1.5 |
1.5 |
10 |
12.5 |
16 |
12.5(18) |
25(30) |
12.8(18) |
Pump Pressure |
KG/CM2 |
2.2 |
2.2 |
2.8 |
3.0 |
3.2 |
5.0(4.0) |
5.0(4.8) |
8.7(7.0) |
Power Supply |
KW |
13 |
20 |
28 |
40 |
50 |
62 |
132 |
162 |
Alert Function |
Shortage/Overheating/Overload |
||||||||
Cooling Water Pipe |
INCH |
1/2 |
1/2 |
1/2 |
1/2 |
1/2 |
1/2 |
3/4 |
3/4 |
Circulation water Pipe |
INCH |
3/4 |
3/4 |
1 |
1-1/4 |
1-1/4 |
1-1/2 |
2 |
2.5 |
Size(L*W*H) |
MM |
L=1150 |
L=1150 |
L=1450 |
L=1600 |
L=1600 |
L=1600 |
L=1600 |
L=1600 |
★ Commissioning & Installation
We offer entire installation and commissioning service until the machine work properly. We offer one year guarantee to buyer, as buyer offer transportation international and boarding charges in local places. After one year, any problem we still will charge for buyer under a reasonable fee